EE Design Flash

dapj Circuits

Electrical and Electronic Measurement Technology
 
  Home  >>  Circuit Applications  >>  NE555 and NE556  >>  NE555 Page 14

Summary
Timing drift W/ Supply Voltage
Typical Timing changes 0.1% per Volt of change in Vcc.

Timing drift W/ Temperature
In Monostable mode the drift is around 50ppm / deg C. In Astable Mode it is 150ppm / deg C as two comparators used.